Products > Medium Voltage Transformers > Medium Voltage Inductors/Reactors
Converter inputs
Grid reactances generally operate in cooperation with power converters in medium voltage electrical systems. They are normally installed on the power supply side (before the converter), in alternating current with a main frequency as the fundamental component. Line inductors are also characterized by the great linearity of their inductance curve (L=f[I]). The mains reactances are produced in accordance with the requirements of the international standards IEC 61558-2-20 / IEC 60076-6.

Converter outputs
Inductors for motors are applied to the outputs of medium voltage frequency converters and motor currents flow through them. They compensate currents with load-reverse capacity in the case of long cables and limit, for suitable long motor cables, the du/dt at the motor terminals, making it possible to supply power to the motor with the longest possible wiring. Motor inductors are produced in accordance with the requirements of international standards IEC 61558-2-20 / IEC 60076-6.
Materials available for download:
REQUEST A PRICE QUOTATION
To request the contact of our team, just leave your details below:
loading...

Converter inputs


- It limits the di/dt slew rate and the impact of changeover switching of converters powered by the same transformer;
- It reduces the harmonic content of the current, providing:
. Increase of power factor;
. Reduction of effective current;
. Reduction of Mains voltage distortion;
. Attenuation of undervoltage or overvoltage transients in the converter network and aid in the action of ultra-fast fuses.
- Insulation class: F (Standard) or B (As per request);
- Protection class: IP-00 (suitable for sheltered installation);
- Frequency: up to 400HZ;
- Terminals: conectors for cables from 1,5 to 10mm虏 or lugs or copper bars for currents greater than 60A;
- Fastening by means of metallic base.


Converter outputs

- Reduction in the du/dt gradient of the voltage at the motor source terminals;
- Cables further away from the motor source are possible;
- Reduction in capacitive current peaks of the load-reverse and consequently the optimal use of the converter capacity;
- Safety for the highest installation;
- Compact design;
- Protection class: IP-00 (suitable for indoor installation);
- Frequency: up to 400HZ;
- Terminals: connectors for cables from 1.5 to 10mm虏 or lugs or copper bars for currents greater than 60A;
- Fastening by means of metallic base.

Converter inputs

They are used on the input side of a drive to protect it from overvoltage transients. The main function of line reactors is to oppose rapid changes in current due to their impedances.


Converter outputs

Standard types can be used for up to 400Hz converter output frequencies and up to 3kHz switching frequency.

See more
Separation Transformer for Medical IT System
Learn more
Autotransformers
Learn more
Low voltage inductors/reactors
Learn more
Residry庐 Dry-type Transformers
Learn more
VPI Phase Transformer
Learn more
K-factor Transformers
Learn more
Medium Voltage Inductors/Reactors
Learn more
Current transformer for measurement
Learn more
Current transformer for protection
Learn more
Potential Transformer
Learn more
Encapsulated phase-shifting transformer
Learn more
TSA15TPA-TSA15TPB
Learn more
TSA25TPA-TSA25TPB
Learn more
Isolator Transformers
Learn more
Single-phase control transformer
Learn more
Single-phase power transformer
Learn more
3-phase control transformer
Learn more
TSA15TCH
Learn more
WHAT DO OUR CUSTOMERS SAY?
I am grateful for Tamura's service, through its professionals who, in all stages of the process of our order, showed great professionalism, competence and elegance. We are very happy with this first experience with your company and we would like it to mark the beginning of a partnership between our companies.
CEZAR T.
Technical Manager, Technology Sector
The reason why we sought Tamura Brasil, was for the quality, reliability and safety of the products.
ALMIR
Buyer, Industrial Sector
Tamura serves us efficiently, has extremely high quality merchandise at a fair price and I recommend it to all of you who are thinking of buying, especially since our time is scarce, we need to be very dynamic, and Tamura becomes a company developed in this sense because it assists us whenever necessary.
RONALDO
Representative, Energy Sector
Download Center
Multimedia Center
REQUEST A PRICE QUOTATION
To request the contact of our team, just leave your details below:
loading...
Follow us on the social networks!
/tamurabrasil
Content
Mais Recentes
Back to start

Somos credenciados nos parceiros:

Logo do Banco Nacional de Desenvolvimento Econ么mico e Social Associa莽茫o Brasileira de Energia Solar Fotovoltaica

Tamura Brasil - Indusul Ind煤stria de Transformadores LTDA

Unidade Santa Catarina - CPNJ: 01.390.877/0001-07

Unidade Minas Gerais - CPNJ: 08.018.660/0001-01